Skip to main content

Move SE Release Notes

Updates on new features, fixes, and known issues for the Move SE family.

Current Firmware Files

01/12/2026

Move SE 12X - v9.1.46Move SE 20X - v9.1.34Move SE 30X - v9.1.39

New Features

Video and Audio Enhancements

  • NDI 6 Upgrade: Upgraded NDI support from NDI 5 to NDI 6 for improved compatibility, performance, and access to the latest NDI protocol features.
  • NDIHX3 Support: Added support for NDIHX3. To enable, set the camera to HDMI-SDI/IP and toggle NDIHX3 to On. HX3 profiles can then be defined as needed.
  • Audio Sample Rate Support: Added support for 44.1 kHz and 48 kHz audio sample rates (previously limited to 32 kHz).
  • Resolved an RTMP issue with compatibility errors when connecting to CDNs related to frame rate, keyframe intervals, and bitrate.
  • Audio Settings Page Reorganized: Encoding and decoding settings were restructured for improved clarity and user experience. Settings are now grouped more logically to help users configure audio more efficiently.

Automation and Control

  • Subject Switching: Added the ability to switch between tracked subjects using left/right arrows via web UI, IR remote, and VISCA joystick commands.
  • Tracking Presets: Added dedicated presets for Auto Tracking control:
Preset 150 = Tracking ON
Preset 151 = Tracking OFF
  • HTTP Movement Status Query: Added a route to allow users to query whether the camera is actively moving. The endpoint returns a boolean response indicating Pan, Tilt, Zoom, or Focus motion.
note

This status does not report focus movement when Auto Focus is enabled.

GET /api/v1/info/is-moving

Example:

GET http://192.168.100.88/api/v1/info/is-moving

Returns:

{
"isMoving": false
}

UI and Systems Changes

  • Guest Access Controls: Guest users are now limited to appropriate routes and no longer have access to SRT or RTMP credentials.
  • Onvif Authentication Default Enabled: ONVIF authentication is now enabled by default to align with updated security protocols and ensure the ONVIF route is protected out of the box.
  • Exposure Bright Mode: Added Bright as an exposure mode option.
  • Updated Encoding Protocol Info Symbol: Added a new info icon next to the Encoding Protocol selection in the web UI. It provides descriptions of each protocol.

Bug Fixes

  • Tracking Sensitivity: Improved tracking stability at full zoom by reducing over-sensitivity to minor subject movements.
  • Pan/Tilt/Zoom Stop Independence: VISCA Pan/Tilt stop commands no longer interrupt Zoom.
  • Home + Navigation Commands: Resolved an issue where recalling Home position followed by HTTP navigation commands caused the camera to stop zooming prematurely.
  • Relative Tilt Bug: Fixed a bug where the camera would tilt up when at the lower tilt limit and receiving a Relative Position Down command.
  • RTMP CDN Errors: Resolved frame rate, bitrate, and keyframe issues blocking some RTMP streaming. Note: When RTMP streaming to YouTube using camera video templates, bitrate errors may occur. Resolution: Adjusting the camera’s video settings to align with YouTube’s video requirements will improve streaming stability and functionality.
  • Snapshot Stability: Fixed a long-term uptime issue where snapshot images would eventually fail.
  • Time Server Application Failures: Fixed behavior where valid NTP time servers (like IPs with .100 octets or certain hostnames) failed through the Web UI but worked via HTTP.
  • NTP Fallback: Fixed a bug preventing consistent NTP server connection after boot, causing fallback to system time.
  • NTP Time Zones: Resolved an issue where certain time zones could not be set from the web UI.
  • Audio Out Menu Simplified: Removed Off option since audio disablement is handled by Audio Codec toggle.

Known Issues

  • Cannot Set Some NTP Servers via Web UI: Some domain strings (for example, time-a-g.nist.gov) fail via Web UI but work using the HTTP API commands.
  • Time Zone Compatibility: Time zone handling may cause SSL certificate renewal failures. Ongoing adjustments are needed.
  • NTP Reboot: Changing the timezone in NTP settings requires a camera reboot.
  • Pan/Tilt Limits Not Persistent: Pan/Tilt Limits are not retained after a reboot; they reset instead of persisting after the reboot.
  • Incorrect VISCA over IP Responses: Changing the Serial VISCA address alters IP response headers (for example, 90 becomes a0, b0, and so on).
  • Pelco P/D Zoom Stop Issue: Pelco P/D Zoom and Focus Stop commands are not received, causing the camera to zoom continuously to its limit.
  • NDI Studio Monitor Hotkeys: Ctrl+Right and Ctrl+Down precision movement do not work. Other Ctrl+Arrow keys function as expected.
  • NDI HX3 Video Template Mismatch: When NDI HX3 is enabled, switching to certain video modes (for example, USB/IP/HDMI-SDI_30FPS) disables HX3 but the Video Template does not reflect the correct available options or default values.
  • NDI HX3 Video Framerate Mismatch: When NDI HX3 is enabled, the Framerate is grayed out, and may not default to 60Hz or 50Hz defined by the certification standards.
  • ONVIF Preview Image Fails: No image preview when HTTP Auth is enabled.

02/13/2025

Move SE 12X - v9.1.43Move SE 20X - v9.1.32Move SE 30X - v9.1.34

New Features and Bug Fixes

  • New Information Symbols: Added symbols for all new features available in the web interface. These symbols provide detailed explanations for each feature.
  • Reorganized Navigation Panel: Organized the navigation panel for improved usability.
  • Dashboard Update: Changed the title Camera Settings to Dashboard in the navigation panel.
  • Privacy Mode: Added a Privacy Mode button to the navigation panel. When enabled, the camera turns away and disables the video feeds. To resume, call a preset or disable Privacy Mode.
  • Power Control: Added a Power On/Off button to the navigation panel of the web interface.
  • Enhanced Tracking Algorithm: Improved the overall tracking algorithm for better accuracy and performance.
  • Changed the title Tracking to Automation under the Control sub-menu.
  • Updated Auto Tracking to Automation in the Control > Automation sub-menu.
  • Renamed Tracking Options to Time Delay.
  • Added the ability to toggle between Auto Tracking and Auto Framing through the Automation dropdown.
  • Introduced a Tracking Stop Location dropdown for more control.
  • Added Target Loss and Target Timeout dropdown options.
  • Added a Target Loss Preset dropdown for preset fallback behavior.
  • Added a new VISCA command for tracked subject selection.
Command: 81 0A 11 A3 0p FF
0x2 = Subject Left
0x3 = Subject Right
0x4 = Confirm Subject
  • Added Time Interval, Preset Range, and Preset Speeds to the Preset Tour function.
  • Changed Audio Out: HDMI to Audio Out: Video Outputs in the Audio & Video section.
  • Enabled editing of Static Fallback Address, Gateway, and Subnet Mask in the Network Settings page.
  • Added NTP Timestamp Overlay and NTP Timestamp Position options in the NTP Settings section.
  • Highlighted the Need Help? button in the Device Information section for better visibility.
  • Improved network security. Guest Login is disabled by default and can be enabled on the System Settings page.
  • Implemented HTTP Authentication: Added Digest Authentication to protect API routes enabled by default.
  • Removed the ability to change the Focus parameters when logged in as a Guest user.
  • Removed OSD access in the web interface when logged in as a Guest user.
  • Resolved an issue with NDI absolute position where previously only the focus functioned. Pan, Tilt, and Zoom are now fully operational for compatibility with programs like Resolume Arena.
  • Fixed an issue with the Move SE cameras where the Manual Focus position was not stored correctly with presets.
  • Addressed a clocking issue between the SDI output of the PTZOptics Move SE cameras and certain SDI equipment.
  • Fixed an issue where the Move SE would zoom to their limits when controlled via Pelco P or D protocols over RS-485 or RS-232.

Known Issues

  • MAC iOS UVC Compatibility: May not be compatible with all MAC applications utilizing YUV formats. Limited to MJPEG UVC.

04/18/2024

Move SE 12X - v9.1.35Move SE 20X - v9.1.26Move SE 30X - v9.1.24

New Features and Bug Fixes

  • Added NDI HX2.
  • Improved the default tracking settings.
  • Resolved an issue on Move SE models where the stop command was not properly triggered when using serial control (RS-232 or RS-485). This caused the camera to continue moving to its limit after releasing the joystick.
  • Fixed a bug where the page icons were placed on the wrong pages.

07/28/2023

Move SE 12X - v9.1.27Move SE 20X - v9.1.21Move SE 30X - v9.1.18

New Features and Bug Fixes

  • Remove Bright in Exposure Mode.
  • In track mode, the live pos is changed to Track Now.
  • When the profiles are full of three, the prompt will be modified.
  • Auto Inversion modifies symbols, pull-down to switch to on|off.
  • Solved the issue that the RS485 is invalid after modifying the VISCA address.
  • Solved the issue that the default Anti-Flicker value of the upgrade 24M upgrade package file is wrong.
  • Solved the issue that when NDI parameters are modified through the web page, after the real-time effect takes effect, the work will be abnormal.
  • Solved the issue of restoring the menu to default, all restoring to default, serial port VISCA does not support visca_setting_reset (81 01 04 A0 10 FF), visca_web_full_setting_reset (81 01 04 A0 20 FF).
  • When the webpage is configured as 2 streams and non-H.264, when previewing and taking snapshots, solved the issue that the snapshots are still going on after closing the webpage.
  • Solved the inconsistency between the address on the RS232 menu and the address code of the command, and added P-P protocol P-D protocol address filtering.
  • Solved the issue of no response code at the network serial port in inversion mode, visca_inversion_mode (81 01 04 a4 0p 00 ff).
  • Solved infrared address query and set VISCA, the serial port is invalid, visca_set_IR_addr (81 0a 11 a7 ff ff), visca_query_IR_addr (81 09 11 a7 ff).
  • Solved the issue that the serial port responded by the SYS_Menu menu is invalid, visca_back_osd_menu(81 01 06 06 04 ff).
  • Solved the issue that the SYS_Menu menu confirms that the serial port is invalid, visca_confirm_osd_menu_two (81 01 06 06 05 ff).
  • Solved the issue that the SYS_Menu menu ON/OFF serial port is invalid, visca_call_osd_menu_two(81 01 06 06 10 ff).
  • Solved the issue that the video system display error when viewing the device information for the first time after switching the language in the menu.
  • Solved the issue of switching languages (*#1 or *#3), the automatic tour and motion synchronization options are not hidden.

06/23/2023

Move SE 12X - v9.1.25Move SE 20X - v9.1.19Move SE 30X - v9.1.17

New Features and Bug Fixes

  • Initial camera firmware.