09/30/2026​

Move SE 12X - v9.1.66Move SE 20X - v9.1.44Move SE 30X - v9.1.46

New Features​

UI and Systems Changes​

  • Image Presets: Added the ability to choose whether preset recalls restore saved image settings along with camera position, or recall the position only while preserving the camera’s current image settings. Image Presets are enabled by default and can be turned on or off from the OSD menu or Web UI.

  • RTSP Stream Info: RTSP Settings are now available in the Web UI. The RTSP Stream URL can also be copied directly for easier integration with external software.

  • Added a field displaying the camera’s Model Name on the System Settings page in the Web UI.

  • Added three new IR commands for adjusting camera control speed when using the IR Remote:

    • [#] > [*] > [F1]: Increase the IR Remote’s control speed by 0%
    • [#] > [*] > [F2]: Increase the IR Remote’s control speed by 10%
    • [#] > [*] > [F3]: Increase the IR Remote’s control speed by 20%
  • Added a PT Limit Reset option to the OSD menu, allowing user-defined Pan/Tilt limits to be reset from the camera menu.

Video and Audio Enhancements​

  • NDI 6 Update: Upgraded NDI support to NDI 6.3 for improved compatibility, performance, and access to the latest NDI protocol features.

  • NDI On / Off Control: Added an NDI On / Off option to the NDI Settings page in the Web UI, allowing users to enable or disable NDI directly from the camera interface.

  • NDI Transmission Protocol Selection: Users can now define the NDI transmission protocol from the Web UI. Options include Reliable UDP (RUDP), TCP, UDP, and Multicast UDP. RUDP is recommended for most use cases.

  • NDI Multicast Info: The NDI Multicast options are now displayed and can be configured from the NDI Settings section of the Web UI.

  • RTMP Startup: Modified the boot-up sequence to prevent the camera from broadcasting RTMP during startup. RTMP will begin after the boot-up sequence is complete.

  • All audio outputs can be disabled via the Audio Codec on/off toggle. Previously, each individual output needed to be toggled.

  • G711 Audio Encoding: Added support for G711 audio encoding to improve interoperability with third-party software systems. G711A is supported, G711U is expected in a future release.

  • Increased SRT Password Length: Expanded the supported SRT password length to 10-79 characters, aligning with SRT standards and improving compatibility with SRT-based workflows.

API and Control Updates​

  • Preset Recall Completion: Added a new Preset recall route that returns a success message when the camera reaches the final location of a recalled preset.
POST /api/v1/action/preset
Body:
{
"action":"recall",
"position":<preset number>
}

Example: POST http://192.168.100.88/api/v1/action/preset
Body:
{
"action":"recall",
"position":1
}
Returns:
{
"msg": "operate success"
}
  • Snapshot Stream Selection: Added support for retrieving snapshots from either stream source, providing users with the option to capture higher-resolution still images while maintaining uninterrupted video performance.

    • GET http://[ipaddress]/snapshot0.jpg → Stream 1
    • GET http://[ipaddress]/snapshot1.jpg → Stream 2
  • P/T Limits Inquiry: Added a query for checking the camera’s current Pan/Tilt Limit settings. The query returns the current coordinates for the minimum and maximum pan and tilt limits.

GET /api/v1/info/pt-limit

Example: GET http://192.168.100.88/api/v1/info/pt-limit
Returns:
{
"panMax": 170.000,
"panMin": -170.000,
"tiltMax": 90.000,
"tiltMin": -30.000
}
  • Preset Inquiry: Added a query for checking the absolute position values of saved camera presets.
GET /api/v1/info/preset/{preset_number}

Example: GET http://192.168.100.88/api/v1/info/preset/1
Returns:
{
"exist": true,
"focusPos": 1026,
"panPos": 42.432,
"tiltPos": -29.239,
"zoomPos": 3294
}
  • VISCA Command Adjustments: Modified the VISCA Privacy Mode on/off and Reboot commands to comply with the standard VISCA command format. Updated Commands:

    • Privacy Mode: 81 01 3F 0A 12 0p FF (p:on = 1,off = 0)
    • Reboot: 81 01 3F 0B 01 AA FF
  • Web UI Logout Fix: Fixed a forced logout issue that could occur when accessing the Web UI within 50 seconds after a reboot.

  • P/T Limit Setting: Pan/Tilt limits now persist through reboots.

  • OSD Control with Auto Tracking/Framing Enabled: Full OSD menu control is now supported with Automation enabled.

  • NDI Studio Monitor Hot Key Support: Fixed an issue where the camera did not respond to precision pan/tilt commands for the right and down directions. All precision pan/tilt commands using Ctrl + [direction arrow] are now supported in Studio Monitor.

  • Device IDs can now begin with numerical characters.

  • MIDI Logout Bug: Fixed an issue where users were logged out of the Web UI after configuring and sending MIDI commands. MIDI command mappings now persist through reboots. Note: MIDI mappings are stored in the browser cache. If the cache is cleared or a new browser is used, previously configured mappings will be unavailable.

  • Stream 2’s default resolution has been changed to 640x360 to address compatibility issues with certain web browsers (eg, Safari).

  • UVC Absolute Position Behavior: Corrected an issue where the camera did not accurately report its absolute position when responding to UVC absolute position inquiries in Windows and macOS.

  • Incorrect VISCA over IP Response: Fixed a bug causing the first byte of the camera’s VISCA response to increment when the serial VISCA address was modified. The camera’s VISCA over IP response is no longer improperly linked to its serial address.

  • Pelco P&D Zoom/Focus Response: Corrected an issue where the camera could miss Pelco P&D Zoom/Focus stop commands, causing Zoom/Focus movement to continue to its limit.

  • Pelco P&D Inquiry Bug: The camera now returns correct responses to Pelco P&D inquiry commands.

Security​

  • Firmware updates now require authentication using the camera’s login credentials. This helps prevent unauthorized users from uploading firmware to the camera.

Known Issues​

  1. Some camera settings may revert to defaults when updating to firmware version 9.1.42. Presets and their included image settings are not affected.

  2. ONVIF Preview Image Fails: No image preview when HTTP Auth is enabled.

  3. Line Out volume changes require a camera reboot before the updated volume setting takes effect.

  4. Audio playback may sound distorted when RTMP streaming directly from the camera to YouTube using camera video templates. For best results, adjust the camera’s video and audio settings to match YouTube’s current recommendations.

Bug Fixes​

  • RTSP Authentication - Guest Access: Fixed an issue that allowed RTSP Authentication to be bypassed using the guest account when the guest account was disabled. RTSP Authentication now correctly requires active user credentials to access RTSP feeds.

  • NDI HX3 Bitrate Display: Corrected a Web UI display issue where the displayed Bitrate would reset to the default value after a reboot when using NDI HX3 (the stream was operating at the user-defined value). The correct Bitrate is now displayed after a reboot.

  • Video Encoding Settings UI Fix: Fixed an issue where the Video Template field did not update correctly and display all available options when reselecting certain Video Output Modes after disabling NDI HX3.

  • SRT Decode Issues: Corrected the SRT packet structure to meet the SRT standard, resolving decode issues with certain SRT decoders.

  • NTP Server Address: Corrected an issue that prevented certain string-based NTP server addresses from being configured through the Web UI.

  • NTP Settings Modification: Fixed an issue where changes to NTP settings (ex: Timestamp overlay, time zone, etc.) required two reboots to take effect. These changes now take effect immediately after clicking Apply (no Reboot required).

  • Network Reset: The Network Reset function now resets all network-related settings in addition to resetting camera login credentials. This includes:

  • IP Configuration (defaults to DHCP mode)

  • Static Fallback IP, Gateway, and Subnet Mask

  • All NTP options (Time Sync, Time Zone, Server Address, Time Interval, etc.)

  • Network Ports (TCP, UDP, HTTP)


07/01/2026​

Move SE 12X - v9.1.56Move SE 20X - v9.1.38Move SE 30X - v9.1.42

Bug Fixes​

  • Incorrect VISCA over IP Response: Fixed a bug causing the first byte of the camera’s VISCA response to increment when the serial VISCA address was modified. The camera’s VISCA over IP response is no longer improperly linked to its serial address.

Known Issues​

  1. Cannot Set Some NTP Servers via Web UI: Some domain strings (e.g., time-a-g.nist.gov) fail via Web UI but work using the HTTP API commands.

  2. Time Zone Compatibility: Time zone handling may cause SSL certificate renewal failures. Ongoing adjustments are needed.

  3. NTP Reboot: Changing the timezone in NTP settings requires a camera reboot.

  4. Pan/Tilt Limits Not Persistent: Pan/Tilt Limits are not retained after a reboot; they reset instead of persisting after the reboot.

  5. Pelco P/D Zoom Stop Issue: Pelco P/D Zoom and Focus Stop commands are not received, causing the camera to zoom continuously to its limit.

  6. NDI Studio Monitor Hotkeys: Ctrl+Right and Ctrl+Down precision movement do not work. (Other Ctrl+Arrow keys function as expected.)

  7. NDI HX3 Video Template Mismatch: When NDI HX3 is enabled, switching to certain video modes (e.g., USB/IP/HDMI-SDI_30FPS) disables HX3 but the Video Template does not reflect the correct available options or default values.

  8. ONVIF Preview Image Fails: No image preview when HTTP Auth is enabled.

  9. Audio embedded over the USB output may sound distorted. To resolve this, set the sample rate to 44.1 kHz or 32 kHz, apply the setting, and reboot the camera. After rebooting, the camera can be set back to 48 kHz if needed.


01/12/2026​

Move SE 12X - v9.1.46Move SE 20X - v9.1.34Move SE 30X - v9.1.39

New Features​

Video and Audio Enhancements​

  • NDI 6 Upgrade: Upgraded NDI support from NDI 5 to NDI 6 for improved compatibility, performance, and access to the latest NDI protocol features.
  • NDIHX3 Support: Added support for NDIHX3. To enable, set the camera to HDMI-SDI/IP and toggle NDIHX3 to On. HX3 profiles can then be defined as needed.
  • Audio Sample Rate Support: Added support for 44.1 kHz and 48 kHz audio sample rates (previously limited to 32 kHz).
  • Resolved an RTMP issue with compatibility errors when connecting to CDNs related to frame rate, keyframe intervals, and bitrate.
  • Audio Settings Page Reorganized: Encoding and decoding settings were restructured for improved clarity and user experience. Settings are now grouped more logically to help users configure audio more efficiently.

Automation and Control​

  • Subject Switching: Added the ability to switch between tracked subjects using left/right arrows via web UI, IR remote, and VISCA joystick commands.
  • Tracking Presets: Added dedicated presets for Auto Tracking control:
Preset 150 = Tracking ON
Preset 151 = Tracking OFF
  • HTTP Movement Status Query: Added a route to allow users to query whether the camera is actively moving. The endpoint returns a boolean response indicating Pan, Tilt, Zoom, or Focus motion.
note

This status does not report focus movement when Auto Focus is enabled.

GET /api/v1/info/is-moving

Example:

GET http://192.168.100.88/api/v1/info/is-moving

Returns:

{
"isMoving": false
}

UI and Systems Changes​

  • Guest Access Controls: Guest users are now limited to appropriate routes and no longer have access to SRT or RTMP credentials.
  • Onvif Authentication Default Enabled: ONVIF authentication is now enabled by default to align with updated security protocols and ensure the ONVIF route is protected out of the box.
  • Exposure Bright Mode: Added Bright as an exposure mode option.
  • Updated Encoding Protocol Info Symbol: Added a new info icon next to the Encoding Protocol selection in the web UI. It provides descriptions of each protocol.

Bug Fixes​

  • Tracking Sensitivity: Improved tracking stability at full zoom by reducing over-sensitivity to minor subject movements.
  • Pan/Tilt/Zoom Stop Independence: VISCA Pan/Tilt stop commands no longer interrupt Zoom.
  • Home + Navigation Commands: Resolved an issue where recalling Home position followed by HTTP navigation commands caused the camera to stop zooming prematurely.
  • Relative Tilt Bug: Fixed a bug where the camera would tilt up when at the lower tilt limit and receiving a Relative Position Down command.
  • RTMP CDN Errors: Resolved frame rate, bitrate, and keyframe issues blocking some RTMP streaming. Note: When RTMP streaming to YouTube using camera video templates, bitrate errors may occur. Resolution: Adjusting the camera’s video settings to align with YouTube’s video requirements will improve streaming stability and functionality.
  • Snapshot Stability: Fixed a long-term uptime issue where snapshot images would eventually fail.
  • Time Server Application Failures: Fixed behavior where valid NTP time servers (like IPs with .100 octets or certain hostnames) failed through the Web UI but worked via HTTP.
  • NTP Fallback: Fixed a bug preventing consistent NTP server connection after boot, causing fallback to system time.
  • NTP Time Zones: Resolved an issue where certain time zones could not be set from the web UI.
  • Audio Out Menu Simplified: Removed Off option since audio disablement is handled by Audio Codec toggle.

Known Issues​

  • Cannot Set Some NTP Servers via Web UI: Some domain strings (for example, time-a-g.nist.gov) fail via Web UI but work using the HTTP API commands.
  • Time Zone Compatibility: Time zone handling may cause SSL certificate renewal failures. Ongoing adjustments are needed.
  • NTP Reboot: Changing the timezone in NTP settings requires a camera reboot.
  • Pan/Tilt Limits Not Persistent: Pan/Tilt Limits are not retained after a reboot; they reset instead of persisting after the reboot.
  • Incorrect VISCA over IP Responses: Changing the Serial VISCA address alters IP response headers (for example, 90 becomes a0, b0, and so on).
  • Pelco P/D Zoom Stop Issue: Pelco P/D Zoom and Focus Stop commands are not received, causing the camera to zoom continuously to its limit.
  • NDI Studio Monitor Hotkeys: Ctrl+Right and Ctrl+Down precision movement do not work. Other Ctrl+Arrow keys function as expected.
  • NDI HX3 Video Template Mismatch: When NDI HX3 is enabled, switching to certain video modes (for example, USB/IP/HDMI-SDI_30FPS) disables HX3 but the Video Template does not reflect the correct available options or default values.
  • NDI HX3 Video Framerate Mismatch: When NDI HX3 is enabled, the Framerate is grayed out, and may not default to 60Hz or 50Hz defined by the certification standards.
  • ONVIF Preview Image Fails: No image preview when HTTP Auth is enabled.

02/13/2025​

Move SE 12X - v9.1.43Move SE 20X - v9.1.32Move SE 30X - v9.1.34

New Features and Bug Fixes​

  • New Information Symbols: Added symbols for all new features available in the web interface. These symbols provide detailed explanations for each feature.
  • Reorganized Navigation Panel: Organized the navigation panel for improved usability.
  • Dashboard Update: Changed the title Camera Settings to Dashboard in the navigation panel.
  • Privacy Mode: Added a Privacy Mode button to the navigation panel. When enabled, the camera turns away and disables the video feeds. To resume, call a preset or disable Privacy Mode.
  • Power Control: Added a Power On/Off button to the navigation panel of the web interface.
  • Enhanced Tracking Algorithm: Improved the overall tracking algorithm for better accuracy and performance.
  • Changed the title Tracking to Automation under the Control sub-menu.
  • Updated Auto Tracking to Automation in the Control > Automation sub-menu.
  • Renamed Tracking Options to Time Delay.
  • Added the ability to toggle between Auto Tracking and Auto Framing through the Automation dropdown.
  • Introduced a Tracking Stop Location dropdown for more control.
  • Added Target Loss and Target Timeout dropdown options.
  • Added a Target Loss Preset dropdown for preset fallback behavior.
  • Added a new VISCA command for tracked subject selection.
Command: 81 0A 11 A3 0p FF
0x2 = Subject Left
0x3 = Subject Right
0x4 = Confirm Subject
  • Added Time Interval, Preset Range, and Preset Speeds to the Preset Tour function.
  • Changed Audio Out: HDMI to Audio Out: Video Outputs in the Audio & Video section.
  • Enabled editing of Static Fallback Address, Gateway, and Subnet Mask in the Network Settings page.
  • Added NTP Timestamp Overlay and NTP Timestamp Position options in the NTP Settings section.
  • Highlighted the Need Help? button in the Device Information section for better visibility.
  • Improved network security. Guest Login is disabled by default and can be enabled on the System Settings page.
  • Implemented HTTP Authentication: Added Digest Authentication to protect API routes enabled by default.
  • Removed the ability to change the Focus parameters when logged in as a Guest user.
  • Removed OSD access in the web interface when logged in as a Guest user.
  • Resolved an issue with NDI absolute position where previously only the focus functioned. Pan, Tilt, and Zoom are now fully operational for compatibility with programs like Resolume Arena.
  • Fixed an issue with the Move SE cameras where the Manual Focus position was not stored correctly with presets.
  • Addressed a clocking issue between the SDI output of the PTZOptics Move SE cameras and certain SDI equipment.
  • Fixed an issue where the Move SE would zoom to their limits when controlled via Pelco P or D protocols over RS-485 or RS-232.

Known Issues​

  • MAC iOS UVC Compatibility: May not be compatible with all MAC applications utilizing YUV formats. Limited to MJPEG UVC.

04/18/2024​

Move SE 12X - v9.1.35Move SE 20X - v9.1.26Move SE 30X - v9.1.24

New Features and Bug Fixes​

  • Added NDI HX2.
  • Improved the default tracking settings.
  • Resolved an issue on Move SE models where the stop command was not properly triggered when using serial control (RS-232 or RS-485). This caused the camera to continue moving to its limit after releasing the joystick.
  • Fixed a bug where the page icons were placed on the wrong pages.

07/28/2023​

Move SE 12X - v9.1.27Move SE 20X - v9.1.21Move SE 30X - v9.1.18

New Features and Bug Fixes​

  • Remove Bright in Exposure Mode.
  • In track mode, the live pos is changed to Track Now.
  • When the profiles are full of three, the prompt will be modified.
  • Auto Inversion modifies symbols, pull-down to switch to on|off.
  • Solved the issue that the RS485 is invalid after modifying the VISCA address.
  • Solved the issue that the default Anti-Flicker value of the upgrade 24M upgrade package file is wrong.
  • Solved the issue that when NDI parameters are modified through the web page, after the real-time effect takes effect, the work will be abnormal.
  • Solved the issue of restoring the menu to default, all restoring to default, serial port VISCA does not support visca_setting_reset (81 01 04 A0 10 FF), visca_web_full_setting_reset (81 01 04 A0 20 FF).
  • When the webpage is configured as 2 streams and non-H.264, when previewing and taking snapshots, solved the issue that the snapshots are still going on after closing the webpage.
  • Solved the inconsistency between the address on the RS232 menu and the address code of the command, and added P-P protocol P-D protocol address filtering.
  • Solved the issue of no response code at the network serial port in inversion mode, visca_inversion_mode (81 01 04 a4 0p 00 ff).
  • Solved infrared address query and set VISCA, the serial port is invalid, visca_set_IR_addr (81 0a 11 a7 ff ff), visca_query_IR_addr (81 09 11 a7 ff).
  • Solved the issue that the serial port responded by the SYS_Menu menu is invalid, visca_back_osd_menu(81 01 06 06 04 ff).
  • Solved the issue that the SYS_Menu menu confirms that the serial port is invalid, visca_confirm_osd_menu_two (81 01 06 06 05 ff).
  • Solved the issue that the SYS_Menu menu ON/OFF serial port is invalid, visca_call_osd_menu_two(81 01 06 06 10 ff).
  • Solved the issue that the video system display error when viewing the device information for the first time after switching the language in the menu.
  • Solved the issue of switching languages (*#1 or *#3), the automatic tour and motion synchronization options are not hidden.

06/23/2023​

Move SE 12X - v9.1.25Move SE 20X - v9.1.19Move SE 30X - v9.1.17

New Features and Bug Fixes​

  • Initial camera firmware.