06/15/2026​

SimplTrack 3 - v1.0.90

Bug Fixes​

  • Firmware Server Updated the default firmware download server to use a secure HTTPS connection, improving the reliability and security of firmware downloads.

  • Automation Toggle Improved the automation toggle label so it now accurately reflects the active mode: Auto Framing in Framing mode and Auto Tracking in Tracking mode.

  • NDI® Settings Validation Message Improved the field requirement error message on the NDI Settings page for clearer configuration guidance.

  • Hardware Stability Fix Improved system stability to help prevent certain cameras from unexpectedly reverting to factory default settings.

Known Issues​

  1. Network Reset - NTP Settings NTP settings do not revert to default values after performing a Network Reset.

  2. VISCA Power Command/Standby Limitation After placing the camera into Standby using the VISCA Power Off command or the IR remote, the camera cannot be powered back on using VISCA over IP. The IR Remote and Serial VISCA commands are unaffected and can power the camera back on.

  3. H.265 Encoding Display Mismatch When any stream (PTZ Stream, Reference Stream, or Stream 3) is set to H.265, all streams output H.265. However, the Web UI does not update the Encoding Profile field for the Reference Stream or Stream 3 accordingly.

  4. Reboot - Password Creation Prompt In rare cases, after rebooting via the Web UI, the new Password Creation prompt may appear unexpectedly and generate an error if a new password is entered. Workaround: Refresh the page to clear the prompt and log in normally.


03/26/2026​

SimplTrack 3 - v1.0.89

New Features​

Tracking Enhancement​

  • Tracking Start/Stop Location Options Added configurable start and stop position options for tracking, allowing users to define the camera’s position when tracking is enabled or disabled within Automation > Settings. Users can select from Presets 0–9, Home, or choose to keep the camera in its current position (“Stay in Place”), providing greater control over camera behavior during tracking transitions.

  • Target Lost Action - Options Added new configuration options for where the camera moves when a tracked subject is lost within Automation > Settings. Available options include Presets 0–9, Home, or Stay in Place.

  • Image Orientation and Inverted Tracking Control in Web UI Added an Image Orientation control under Image > Advanced in the Web UI Dashboard. Previously, this setting was only available through the OSD menu. The available options are Flip, Mirror, and Flip & Mirror. Flip & Mirror settings allow the camera to be installed in an inverted position and support inverted tracking operation.

Behavior Notes​

  • Zoom While Tracking: Enabled - Composition Behavior When Zoom While Tracking is enabled, the camera’s zoom level and subject framing are determined by the Zoom Limit setting (values 0–7):

  • 0–2: Close-up view

  • 3–5: Half-body view

  • 6–7: Whole-body view Value 4 is recommended for typical use cases.

  • Zoom While Tracking: Disabled – Preset Behavior When Zoom While Tracking is disabled, the camera uses Preset 1 (Subject Preset) to determine the zoom level during tracking.

  • Tilt While Tracking Disabled - Zoom Behavior When Tilt while Tracking is set to Off, zoom adjustments are disabled during tracking. The camera maintains the zoom level defined by preset 1.

Bug Fixes​

  • Inverted Mount: Tracking/Framing Resolved an issue that prevented Auto Tracking and Framing from operating when the SimplTrack 3 was mounted in an inverted position.

  • White Balance: VAR Settings reset after a Reboot Fixed an issue where VAR settings would reset after a Reboot.

Web UI Updates & Fixes​

  • Hive Studio 404 Error Resolved an issue where the Hive Studio page returned a 404 error on first access.

  • Digital Zoom Field Display (Web UI) Corrected a display issue where the Digital Zoom field did not populate with the default “Off” setting.

  • NDI® Settings Validation Message Improved the field requirement error message on the NDI Settings page for clearer configuration guidance.

Known Issues​

  1. Network Reset - NTP Settings NTP settings do not revert to default values after performing a Network Reset.

  2. VISCA Power Command/Standby Limitation After placing the camera into Standby using the VISCA Power Off command or the IR remote, it cannot be powered back on via either VISCA or the IR remote. A power cycle is required.

  3. H265 Encoding Display Mismatch When any stream (PTZ Stream, Reference Stream, or Stream 3) is set to H.265, all streams output H.265. However, the Web UI does not update the Encoding Profile field for the Reference Stream or Stream 3 accordingly.

  4. Reboot - Password Creation Prompt In rare cases, after rebooting via the Web UI, the new Password Creation prompt appears unexpectedly and generates an error if a new password is entered. Workaround: Refresh the page to clear the prompt and log in normally.


12/19/2025​

SimplTrack 3 - v1.0.85

New Features​

HIVE Linked Integration​

  • HIVE Linked Enabled: The camera now includes HIVE Linked, allowing users to connect directly to the PTZOptics HIVE platform. This integration unlocks powerful remote management, monitoring, and collaboration capabilities, providing users with centralized access to camera control, status monitoring, and multi-location coordination through the cloud. For more information, visit Hive Studio

Video Configuration​

  • Stream 3 Definition Added to Web UI Users can now define Stream 3 (Low Bandwidth PTZ video feed) directly in the Web UI under Audio & Video settings.

Bug Fixes​

  • NDI Low Bandwidth Mode – Reference Stream Resolved an issue where NDI Low Bandwidth Mode did not function properly on the Reference Stream.

  • NDI Audio Transport Fixed an issue where audio was not being transported over the NDI stream.

  • Reference Lens Settings Persistence Corrected a problem where Image, Exposure, and Color settings on the Reference Lens reverted to default on reboot. These settings now persist correctly.

  • Independent Saturation Control Fixed an issue where adjusting Saturation on the Reference View also changed the PTZ Lens saturation. Both are now independently controlled.

  • Preset Naming Behavior Updated The Set button now saves both the preset location and the preset name. Previously, naming required an additional workaround.

  • TCP Default Port Correction The default TCP port now correctly initializes to 5678 instead of 1259.

  • Target Lost Action – Incorrect Preset Behavior Fixed an issue where the camera failed to call Preset 0 (Stage Preset) after the target-lost timeout and instead stayed in place. Additionally, when “Stay in Place” was selected, the camera incorrectly called Preset 2. These form selections were reversed; they now match the intended behavior.

  • Zoom While Tracking – Default Behavior Updated Zoom While Tracking is now enabled by default to improve auto-tracking responsiveness and subject framing.

  • Preset Control Character Input Bug Resolved an issue where the Preset Control text field on the main Dashboard allowed non-numeric characters. The field now strictly accepts numeric input only.

  • Tracking Outside Reference View – Incorrect Behavior Resolved Corrected an issue where tracking behavior was inconsistent when no Reference Area was defined:

    • With Zoom While Tracking Off and Track Outside Ref. View Off, tracking should stop when the subject exits the Reference lens’ field of view.
    • With Zoom While Tracking On and Track Outside Ref. View Off, the camera incorrectly continued tracking outside the Reference View. This has now been fixed so behavior is consistent.
  • Device ID / NDI Local Device Name Synchronization Resolved an issue where changing the NDI Local Device Name (e.g., from ptzoptics to ST3-Test-1) did not persist after a reboot, while changes made to the Device ID under the Device Info tab did apply correctly. Both fields now function together—updating either the NDI Local Device Name or the Device ID will correctly update both name fields and persist through reboot.

  • Incorrect Password Creation Prompt After Reboot - Fixed an issue where rebooting the camera from the Web UI caused the page to reload with an unexpected password creation prompt.

Known Issues​

  1. RTMP Stream 2 & 3 Green Screen Issue If a green screen appears when using Stream 2 or 3, switch back to Stream 1 before selecting the desired stream.

  2. VAR Setting Reversion on Reboot (PTZ & Reference Lens) VAR-based settings revert to 3200K after reboot. The slider will not update to reflect this, even though the actual color temperature resets.

  3. Hive Linked Browser Error The first time Hive Linked is selected in the side menu, a browser error may appear. Switching tabs and reselecting Hive resolves the issue.

  4. Tracking Disabled When Camera Is Inverted Tracking does not function when the camera is mounted upside-down.

  5. Digital Zoom Field Not Populated by Default The Digital Zoom field does not populate Off by default and appears blank on initial load.

  6. Mislabeled “Target Lost Action” Field - The Target Lost Action field is incorrectly titled. This field actually refers to both the camera’s Startup Action and Target Lost Action, and will be updated in a future release to accurately reflect both functions.

  7. H.265 Encoding Behavior Across Streams: When selecting H.265 on Stream 2 or Stream 3, the PTZ Output Stream must also be set to H.265 for the codec to function across all streams.


09/16/2025​

SimplTrack 3 - v1.0.82

New Features and Bug Fixes​

  • Compatibility & Certification: Firmware can now be applied to both PTZOptics cameras and HuddleCamHD models, ensuring unified support and easier maintenance. The camera has also successfully passed the official NDI HX2 Certification program, ensuring compliance and verified compatibility.
  • Audio Output Over IP & NDI: Resolved an issue where audio did not play over NDI. Audio is now confirmed to be working over NDI.
  • Preset 1-9 Group Naming: Fixed an issue where names assigned to presets 1-9 were not retained after reboot and behaved as group names rather than individual preset labels.
  • Baud Rate Reset: Fixed an issue where the baud rate would automatically change to 2400 after position correction was completed.
  • TCP Port & Protocol: Corrected default Control settings so the camera now uses port 5678 and TCP as the default protocol.
  • Saturation in Reference View: Corrected behavior where Saturation adjustments in the reference view incorrectly affected the PTZ view. Now, unavailable image adjustments are greyed out when the camera is set to reference view.
  • Zoom While Tracking: Fixed an issue where the camera continued to zoom in and out even when Zoom While Tracking was disabled.
  • NDI Low Bandwidth Mode: Fixed an issue where NDI low bandwidth mode did not function correctly on the reference stream.
  • Preset Save Workflow: Fixed an issue where presets could not be renamed during the save process. Presets can now be saved and renamed by clicking Set or pressing Enter.

Known Issues​

  • Reference Lens Settings: Image, exposure, and color settings on the reference lens do not save after reboot.
  • Exposure Settings: Exposure adjustments do not persist after reboot and revert back to Auto Exposure.
  • Zoom & Tracking Interaction: If Zoom While Tracking is enabled and Track Outside Reference View is disabled, the camera may continue to track outside the reference view.
  • Gesture Control: Zoom may not function as expected when Gesture Control is enabled.

07/30/2025​

SimplTrack 3 - v1.0.81

Bug Fixes​

  • Addressed an issue with high bandwidth and low bandwidth stream mismatch.
  • Resolved an issue where NDI low bandwidth mode was not functioning on the PTZ stream.
  • Corrected static fallback behavior to default to 192.168.100.88 instead of 192.168.1.180.
  • Resolved issue where some camera presets could not be overwritten.
  • Fixed a bug where using the Apply button on Zone Settings (Preset Zone, Tracking Zone, or Blocking Zone) would disable any enabled Preset Zones functions.
  • Resolved issue where the NDI device name would not save after reboot.
  • Fixed multiple instances of the Discovery Server being referenced simultaneously.
  • Corrected issue where the firmware update server could not download new firmware to the local PC.

Known Issues​

  • NDI low bandwidth mode does not function on the Reference Stream.
  • Audio does not transmit over NDI.
  • RTMP issue: If a green screen appears when using Stream 2 or 3, the user must return to Stream 1 before switching.
  • Reference Lens: Image, exposure, and color settings on the Reference Lens do not save after reboot.
  • When making adjustments to Exposure settings, it will not save after a reboot and revert back to Auto Exposure.
  • Adjusting saturation in the Reference View affects the PTZ View instead of the intended Reference View.
  • When saving a preset and renaming it, the Set button does not save the name, and pressing Enter does not save the preset. Workaround: Move the camera to the desired location, enter the preset number and press Set, then type the preset name and press Enter.
  • If Zoom While Tracking is on and Track Outside Ref. View is off, the camera will continue to track outside the reference view.
  • When Gesture Control is enabled, zoom may not function as expected.

06/06/2025​

SimplTrack 3 - v1.0.79

New Features and Bug Fixes​

  • Upgraded the firmware of the HuddleCamHD SimplTrack 3 to the new PTZOptics SimplTrack 3 version. This update includes a new Web UI, accessible at ptzoptics.local or via the camera's IP address.
  • Introduced new SimplTrack Control Software to monitor and configure all SimplTrack products (formerly known as CMS).
  • Fixed a bug preventing TCP and UDP control from working properly.

Known Issues​

  • No audio over NDI stream.
  • After a reboot, changes made to the reference view will revert to default.
  • Static fallback may revert to 192.168.1.180.
  • The web interface doesn't properly set zones when the browser is zoomed in or out past 100%.
  • Traversing the OSD with VISCA commands requires you to send the Stop command to continue traversing.
  • The NDI Local Device Name can only be changed on the Device Settings page.
  • If the camera is set to DHCP and you click the Apply / Save button on the Network Settings page, the camera will acquire a new IP address even if the network type hasn't changed.
  • Changing the resolution requires the camera to be rebooted.

Ask PTZOptics AI

Ask a question about PTZOptics products or documentation.